External Reference Parameters
FQ2-S4 User’s Manual
513
Appendices
12
125 Output
parame-
ter
String output on/off Settings/
Acquisition
0: None
1: Enable
0 --- ---
127
*1
Error string Settings/
Acquisition
20 characters max NG --- ---
128 Partial output on/off Settings/
Acquisition
0: None
1: Enable
0 --- ---
129 Output last digit Settings/
Acquisition
1 to 1024 1024 --- ---
130 Output first digit Settings/
Acquisition
1 to 1024 1 --- ---
131 Mea-
sure-
ment
result
Code type Settings/
Acquisition
0: JAN/EAN/UPC
1: Code 39
2: Codabar
3: ITF
4: Code 93
5: Code128/GS1-128
6: GS1 DataBar
7: Pharmacode
0 --- ---
132 Timeout time (ms) Settings/
Acquisition
1 to 9999 9999 --- ---
133 Check digit on/off Settings/
Acquisition
0: None
1: Enable
1 --- ---
134 Composite codes on/off Settings/
Acquisition
0: None
1: Enable
0 --- ---
135 Direction Settings/
Acquisition
0: Horizontal mode
1: Vertical mode
0 --- ---
136 Reverse on/off Settings/
Acquisition
0: None
1: Enable
0 --- ---
150 Verifica-
tion con-
dition
Selected master num-
ber
Settings/
Acquisition
1 to 31 0 --- ---
152 Auto master data num-
ber
Setting/Acqui-
sition
0 to 31: Master data num-
ber
1: OFF
1 --- ---
170 Output
parame-
ter
String output ON/OFF
(memory link)
Setting/Acqui-
sition
0: OFF, 1: ON 0 --- ---
171 NG error code output
(memory link)
Setting/Acqui-
sition
0: OFF, 1: ON 1 --- ---
172 Partial output ON/OFF
(memory link)
Setting/Acqui-
sition
0: OFF, 1: ON 0 --- ---
173 Output end digit (mem-
ory link)
Setting/Acqui-
sition
1 to 128 128 --- ---
174 Output beginning digit
(memory link)
Setting/Acqui-
sition
1 to 128 1 --- ---
202+3N
(N=0 to
31)
Verifica-
tion con-
dition
Master data N Settings/
Acquisition
32 characters max. None --- ---
300+N
(N=0 to
31)
Reference unit number
N
Setting/Acqui-
sition
0 to 31 0 --- ---
410 Logging
condi-
tions
Data logging switch for
unit
Setting/Acqui-
sition
0: Data logging OFF
1: Data logging ON
1 --- ---
411 Data logging switch for
judgement
Setting/Acqui-
sition
0: Data logging OFF
1: Data logging ON
1 --- ---
412 Data logging switch for
number of characters
Setting/Acqui-
sition
0: Data logging OFF
1: Data logging ON
1 --- ---
External
refer-
ence
number
Category Data name Setting/Acqui-
sition
Data range Default Expres-
sion text
string
Logged data/
Judgement
parameter

Table of Contents