5-3-5 HOLD (Operating Mode F7)
If HOLD input is ON, the counting value is on hold.
The K3NR is in counting operation continuously while HOLD input is ON and
comparative output and BCD data are available regardless of the HOLD input.
The HOLD indicator is lit while HOLD input is ON.
Input pulse
Display
External Input Signals