205
Various System Settings
Section 6-9
Reference - If a communication error occurs when OFF is set for Comm. Auto-return, the
NT31/NT31C makes the number of attempts at communication with the host
specified by the setting for the Retry Counts touch switch (page 207). If com-
munication cannot be re-established in any of these attempts, an error screen is
displayed.
- For details on communication errors, refer to 11-2-5 Communication Errors and
Their Remedies (page 629).
Set the automatic reset function by following the menu operation from the System
Menu shown below.
Select “Maintenance Mode”.
Select Memory Switch”.
Press [ ] (next screen) or [ ] (previous
screen) to display the third memory switch
setting screen.
Press “Comm. Auto-return to display the re-
quired setting.
The setting option changes each time the
touch switch is pressed.