259
NT31/NT31C Screen
Section 7-1
S Load Local1, Load Local2
Specify whether or not a window (Local1, Local2) pops up at the same time the
screen is displayed by screen switching. Set the window screen number to be
displayed when you check these attribute.
For details of a window, refer to 7-14 Window Function (page 438), and for de-
tails of using method of a window, refer to 8-4 Display and Control of Windows
(page 490)
Reference - A window can also be opened, closed or moved by the operation at Window
control area (refer to page 493)
- To control (open close or move) a window, follow the methods below.
@ Register Input key-Window/Keyboard touch switch or Window Move touch
switch on ascreen. (refer to page 491, 493)
@ Register Cursor Move touch switch which has a window open function. (refer to
page 492)
@ Operate Window control area from the host. (refer to page 493)
@ Switch to the screen which has Load Local1 (keyboard) or Load Local2
screen attribute.