5-29
5-10 User Parameters
5
Operating Functions
Sequence Parameters
Pn
No.
Parameter
name
Setting Explanation
Default
setting
Unit
Setting
range
Power
OFF
ON
60
Positioning
Completion
Range
Set the range for the Positioning Completed Output
(INP).
25 Pulses
0 to
32767
---
61
Zero Speed
Detection
Set the rotation speed for the Warning Output for
zero speed detection.
20 r/min
0 to
20000
---
62
Rotation Speed
for Servomotor
Rotation
Detection
Set the rotation speed for the Servomotor Rotation
Speed Detection Output (TGON) for Internally Set
Speed Control.
50 r/min
0 to
20000
---
63
Deviation
Counter
Overflow Level
Set the detection level for the Deviation Counter
Overflow Alarm. The alarm level is the setting value
multiplied by 256 pulses.
100
× 256
pulses
0 to
32767
---
64
Deviation
Counter
Overflow Alarm
Disabled
Enable or disable the Deviation Counter Overflow
Alarm.
0 --- 0 or 1 ---0
Deviation Counter Overflow Alarm en-
abled.
1
Deviation Counter Overflow Alarm dis-
abled.
65 Not used. (Do not change setting.) 0 --- --- ---
66
Stop Selection
for Drive
Prohibit Input
Set the operation used to decelerate to a stop after
the Forward Drive Prohibit Input (POT) or Reverse
Drive Prohibit Input (NOT) is turned ON.
0 --- 0 to 2 Yes
0
The torque in the drive prohibit direction is
disabled, and the dynamic brake is acti-
vated.
1
The torque in the drive prohibit direction is
disabled, and free-run deceleration is per-
formed to stop.
2
A servo lock stop is used in position con-
trol, and a zero-speed designation stop is
used in Internally Set Speed Control.
67 Not used. (Do not change setting.) 0 --- --- ---
68
Stop Selection
at Alarm
Set the operation to use during deceleration and af-
ter stopping when an alarm occurs. The value of the
deviation counter is held when an alarm occurs.
The deviation counter is cleared when the alarm is
reset.
0 --- 0 to 3 ---
0
During deceleration: Dynamic brake
After stopping: Dynamic brake
1
During deceleration: Free run
After stopping: Dynamic brake
2
During deceleration: Dynamic brake
After stopping: Servo free
3
Duri
ng deceleration
: Free run
After stopping: Servo free

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SMARTSTEP 2 R88M-G Series and is the answer not in the manual?

Omron SMARTSTEP 2 R88M-G Series Specifications

General IconGeneral
BrandOmron
ModelSMARTSTEP 2 R88M-G Series
CategoryServo Drives
LanguageEnglish

Related product manuals