EasyManua.ls Logo

Omron SMARTSTEP 2 R88M-G Series - Page 304

Omron SMARTSTEP 2 R88M-G Series
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8-7
8-3 Troubleshooting
8
Troubleshooting
14 Overcurrent Occurs when the Servo
Drive is turned ON.
Control PCB error Replace the Servo Drive.
Servomotor power line is
short-circuited or ground-
faulted between phases.
Repair the short-circuited
or ground-faulted wire.
Measure the insulation
resistance at the Servo-
motor and, if there is a
short-circuit, replace the
Servomotor.
Miswiring between
phase U, V, or W and
ground.
Correct the wiring.
Servomotor winding is
burned out.
Measure the wire wound
resistance, and if the
winding is burned out, re-
place the Servomotor.
The relay for the dynamic
brake has been conse-
quently welded.
Do not frequently input
the RUN Command In-
put.
Do not operate the sys-
tem by turning the Servo
Drive ON and OFF.
Servomotor non-confor-
mity
Use a Servomotor that is
appropriate for use with
the Servo Drive.
The pulse input timing is
too fast.
Wait 100 ms min. before
inputting pulses after
turning ON the RUN
Command Input (RUN).
The resistor in the Servo
Drive is abnormally over-
heating.
Reduce the ambient tem-
perature of the Servo
Drive to 55°C or lower.
If the relay does not click
when the power supply is
turned ON, replace the
Servo Drive.
16 Overload Occurs when the Servo
Drive is turned ON.
There is an error in the
Servomotor wiring (e.g.,
the wiring or the contacts
are faulty).
Wire the Servomotor
Power Cable correctly.
The electromagnetic
brake is ON.
Reset the brake.
The Servo Drive is faulty. Replace the Servo Drive.
Occurs during opera-
tion.
The actual torque ex-
ceeds the rated torque.
The starting torque ex-
ceeds the maximum
torque.
Review the load condi-
tions and operating con-
ditions.
Review the Servomotor
capacity.
An unu
sual noise
oscilla-
tion or vibration is caused
by faulty gain adjustment.
Adjust the gain correctly.
The Servo Drive is faulty. Replace the Servo Drive.
Alarm
code
Error
Status when error
occurs
Cause Countermeasure

Table of Contents

Related product manuals