8-11
8-3 Troubleshooting
8
Troubleshooting
95 Servomotor
non-conformity
Occurs when the power
supply is turned ON.
• The Servomotor and
Servo Drive combination
is incorrect.
• Use a correct combina-
tion.
• The encoder wiring is
disconnected.
• Wire the encoder.
• Fix the locations that are
disconnected.
96 LSI setting error • Incorrect operation due
to noise.
• Take measures against
noise.
Others Other errors --- • The Servo Drive’s self-di-
agnosis function detect-
ed an error in the Servo
Drive.
• Turn OFF the power sup-
ply and turn it ON again.
• Replace the Servomotor
or Servo Drive.
Alarm
code
Error
Status when error
occurs
Cause Countermeasure