Appendix-2
App
Appendix
Connection Example 2: Connecting to SYSMAC CJ1W-NC113/213/413 Position
Control Units
No.
CN1CNA
A1
A2
23
24
25
4
14
21
10
1
2
13
9
11
22
L1
L2
U
V
W
GND
INP
RUN
0GND
/ALM
FG
Z
A8
A7
A6
A5
A9
A13
A12
A11
A20
A15
A17
A19
A18
A16
CN2
M
E
X1
XB
24 VDC
24 VDC
24 VDC
B
BKIR
CNB
L3
24 VDC
XB
B1
P
26
X1
CJ1W-NC113/213/413
Contents
24-V power supply for outputs
0-V input (for output)
X-axis dev. cntr. reset output
X-axis origin input (24 V)
X-axis origin common
X-axis positioning complete input
X-axis input common
ECRST
CCW (with a resistor)
CCW (without a resistor)
CW (with a resistor)
CW (without a resistor)
3-phase 200/240 VAC 50/60 Hz
X-axis
pulse output
X-axis external interrupt input
X-axis origin proximity input
X-axis CCW limit input
X-axis CW limit input
X-axis emerg. stop input
Noise filter
(Ground to
100 Ω or less.)
Reactor
R7D-BP@
Connect External Regeneration
Resistor when required.
R7A-CPB@S
Servomotor Power
Cable
R7A-CAB@S
R88M-G@
+CW
−CW
+24VIN
Red
White
Blue
Green/
Yellow
+CCW
−CCW
Encoder Cable
R88A-CRGB@C
Brake Cable
R88A-CAGA@B
R
T
NFB
ONOFF
X1
MC1
MC1
PL
S
X1
SUP
MC1
Main circuit
power supply
Main circuit contactor
Servo error display
Surge suppressor
Incorrect signal wiring can cause damage to Units and the Servo Drive.
Leave unused signal lines open and do not wire them.
Use mode 2 for origin search.
Use the 24-VDC power supply for the command pulse inputs as a
dedicated power supply.
Do not share the power supply for brakes (24 VDC) with the 24-VDC power
supply for controls.
Recommended surge absorption diode: RU2 (Sanken Electric) or the
equivalent
Precautions
for Correct Use