331
PLC Comparison Charts Appendix A
Initial
set-
tings
I/O Input response time
for Basic I/O Unit
Set in PLC Setup Set in PLC Setup No No Set in PLC
Setup
Rack first addresses Set in I/O table from
Programming Device
(but order of rack
numbers is fixed).
Set in I/O table
from Program-
ming Device (but
order of rack
numbers is fixed).
No Set in PLC
Setup (Rack
No. order can
be set.)
No
First address of SYS-
MAC BUS Optical I/O
Units by Master
No No No Set in PLC
Setup
No
Operation for I/O ver-
ification error
No No No Set in PLC
Setup
No
Mem-
ory
User memory protec-
tion
Set on DIP switch Set on DIP switch Set on DIP
switch
Determined by
key switch set-
ting
Set on DIP
switch
Holding areas No No No Set in PLC
Setup
No
Holding I/O words for
fatal errors (except
power failure)
No No No Set in PLC
Setup
No
Memory saved using
IOM Hold Bit when
power to PLC is
turned ON
Set in PLC Setup Set in PLC Setup Set in PLC
Setup
Set in PLC
Setup
Set in PLC
Setup
Memory saved using
Forced Status Hold
Bit when power to
PLC is turned ON
Set in PLC Setup Set in PLC Setup Set in PLC
Setup
Set in PLC
Setup
Set in PLC
Setup
DIP switch status
monitoring
Yes Yes Yes No Yes
Instruc-
tions
Setting indirect DM
data to BCD or
binary
Direct input possible Direct input pos-
sible
No Set in PLC
Setup
No
Multiple use of
JMP(0) instruction
Multiple use already
possible
Multiple use
already possible
No Set in PLC
Setup
No
Operation for instruc-
tion errors (Continue
or stop)
Set in PLC Setup Set in PLC Setup No No No
Background execu-
tion
CJ1: No
CJ1-H: Yes
CJ1M: Yes
CS1: No
CS1-H: Yes
No No No
File
mem-
ory
Automatic transfer at
startup
Determined by DIP
switch setting (Auto-
matically read from
Memory Card)
Determined by
DIP switch set-
ting (Automati-
cally read from
Memory Card)
Determined by
DIP switch set-
ting (Automati-
cally read from
memory cas-
sette)
Set in PLC
Setup or DIP
switch setting
(Automatically
read from
Memory Card)
Determined by
DIP switch set-
ting (Automati-
cally read from
Memory Card)
Convert to EM file Set in PLC Setup Set in PLC Setup No No No
Inter-
rupts
Interrupt response No No Set in PLC
Setup
(C200H/High-
speed
response)
No No
Error detection Set in PLC Setup Set in PLC Setup Set in PLC
Setup
No No
Holding I/O inter-
rupts during I/O inter-
rupt program
execution
No No No Set in PLC
Setup
No
Power OFF interrupt
enabled/disabled
Set in PLC Setup Set in PLC Setup No Set in PLC
Setup
No
Scheduled interrupt
interval setting
Set in PLC Setup
(10 ms, 1.0 ms) (also,
0.1 ms for CJ1M CPU
Unit only)
Set in PLC Setup
(10 ms, 1.0 ms)
Set in PLC
Setup
Set in PLC
Setup (10 ms,
1 ms, 0.5 ms)
No
Item CJ Series CS Series C200HX/HG/
HE
CVM1/CV
Series
CQM1H

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC CS/CJ Series and is the answer not in the manual?

Omron SYSMAC CS/CJ Series Specifications

General IconGeneral
BrandOmron
ModelSYSMAC CS/CJ Series
CategoryController
LanguageEnglish

Related product manuals