13
1.2. Applicable Load Cells
The table below shows the specifications of the NX-RS1201 Load Cell Input Unit used for
explanation in this Guide. Select the applicable load cell within the range of specifications as
shown in the table.
Load cell excitation
voltage
Input range
Connection to load
cell
Number of load cell
input
5 VDC ±10%
Output current: 60mA
or less
-5.0 to +5.0 mV/V 6-wire type or 4-wire
type
1
For use of a load cell for which a load cell excitation voltage of more than 5 VDC is
recommended, ask the load cell’s manufacturer if the use of 5 VDC is acceptable.
*1
You cannot
use a load cell whose load cell excitation voltage is less than 5 VDC in its specifications.
For use of multiple load cells in parallel connection, the total current supplied to the load cell
should be 60 mA or less.
*1. For example, if the load cell excitation voltage is specified as 5 to 10 VDC in the
specifications, its use is possible. If specified as 10 VDC, ask the load cell’s manufacturer if
the use of 5 VDC is acceptable.

Other manuals for Omron SYSMAC NX series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC NX series and is the answer not in the manual?

Omron SYSMAC NX series Specifications

General IconGeneral
BrandOmron
ModelSYSMAC NX series
CategoryController
LanguageEnglish

Related product manuals