48
SECTION 4
Command/Response Format
CIDRW System
User’s Manual
SECTION 4
Reading from/Writing to ID Tags
■ RESET
All Amplifier Unit processing is stopped, and the initial status is re-established.
There is no response to this command.
■ SET WEB PASSWORD
This command sets the Web password.
If you set a password, a Password entry window will be displayed when you start the browser window.
When the Password Is Not Set
* Only the following characters can be used in passwords: 0 to 9, a to z, and A to Z. If any other characters are used, error 14 will
occur.
* If the password is not between 1 and 16 characters long, error 14 will occur.
When the Password Is Not Set
Never turn OFF the power supply to the Amplifier Unit before a response is received from the Amplifier Unit for this
command. Doing so may damage the Amplifier Unit.
The values are enabled when the Amplifier Unit is restarted.
Command code CR
7F0Dh
Command code Password (1 to 16 characters) CR
A2 0Dh
Command code CR
A20Dh
Response
code
CR
000Dh