49
CIDRW System
User’s Manual
SECTION 4
Command/Response Format
SECTION 4
Reading from/Writing to ID Tags
SET NETWORK
This command sets the IP address and subnet mask in ROM.
* If an error occurs when writing to EEPROM, error 9A will be returned.
Never turn OFF the power supply to the Amplifier Unit before a response is received from the Amplifier Unit for this
command. Doing so may damage the Amplifier Unit.
The values are enabled when the Amplifier Unit is restarted.
Command code First octet Second octet Third octet Fourth octet CR
A3 0Dh
Parameter Description
Parameter Description
Type IP address setting: 00
Subnet mask setting: 01
First to fourth octets The address is set in decimal in four octets of three characters each.
Response
code
CR
000Dh
Command
Response