EasyManuals Logo

Omron V680 Series User Manual

Omron V680 Series
344 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #23 background imageLoading...
Page #23 background image
RFID System
User's Manual
(Modbus TCP)
Section 1 Application Flowchart
Section 1
Product Overview
21
p.95
Setting Reader/Writer Communications Conditions
Change the network settings of the host device to match those of the Reader/Writer.
Host Device Setting Example
IP address: 192.168.1.100
Subnet mask: 255.255.255.0
he default network settings for the Reader/Writer are listed in the following table.
IP address 192.168.1.200
Subnet mask 255.255.255.0
Default gateway 192.168.1.254
Port number 502
Port number for Web browser 7090
Start a Web browser (e.g., Internet Explorer) on the host computer, enter http://192.168.1.200/ in the address box, and press the
Enter Key. Communications will be possible if the following view appears.
p.102
Communications Test with Host Device
Communications Preparations
Trial Operation

Table of Contents