Table 23-5 (Cont.) Estimated Load Times of ABCEG251-11 (Part Number
700247-092-PT)
Load
Item
10%
Load
Time
20%
Load
Time
30%
Load
Time
40%
Load
Time
50%
Load
Time
60%
Load
Time
70%
Load
Time
80%
Load
Time
90%
Load
Time
100%
Load
Time
Watts 17.5 3 52.5 70 87.5 105 122 140 158 175
Run
Time
(Mins)
140 48 56 43 23 19 16 13 12 10
Table 23-6 Estimated Load Times of ABCEG401-11 (Part Number 700247-093-
PT)
Load
Item
10%
Load
Time
20%
Load
Time
30%
Load
Time
40%
Load
Time
50%
Load
Time
60%
Load
Time
70%
Load
Time
80%
Load
Time
90%
Load
Time
100%
Load
Time
Volts 122 121 120 121 122 121 121 121 120 119
Amps 0.24 0.46 0.70 0.92 1.15 1.40 1.63 1.88 2.10 2.36
Watts 28 5 84 112 140 168 196 224 252 280
Run
Time
(Mins)
65 30 28 19 15 13 11 8 7 6
Table 23-7 Estimated Load Times of ABCEG601-11 (Part Number 700247-094-
PT)
Load
Item
10%
Load
Time
20%
Load
Time
30%
Load
Time
40%
Load
Time
50%
Load
Time
60%
Load
Time
70%
Load
Time
80%
Load
Time
90%
Load
Time
100%
Load
Time
Volts 122 122 121 121 121 122 121 121 116 114
Amps 0.35 0.69 1.04 1.39 1.74 2.07 2.44 2.78 3.26 3.66
Watts 4 84 126 168 210 252 294 336 378 420
Run
Time
(Mins)
90 55 39 30 24 18 14 11 19 7
Table 23-8 Estimated Load Times of ABCEG800-11 (Part Number 700247-095-
PT)
Load
Item
10%
Load
Time
20%
Load
Time
30%
Load
Time
40%
Load
Time
50%
Load
Time
60%
Load
Time
70%
Load
Time
80%
Load
Time
90%
Load
Time
100%
Load
Time
Volts 118 119 118 118 117 119 118 118 118 120
Amps 0.44 0.87 1.32 1.76 2.21 2.63 3.08 3.52 3.94 4.36
Watts 5 110 165 224 280 335 395 450 500 560
Chapter 23
PowerVar Single Phase Desktop UPS - Estimated Run Times
23-6