Command for changing input mode without screen scaling -
It is available only on Power On (Operative) status.
-
CMD: 0xDD(DVI), 0XDE(PC), 0XE2(Video)
-
Send to MLCD
-
NormalCommandA.
STX CMD Length
Data
ETX
ID Master XY X
Value 0x02 Variable 0x04 Variable 0X01 0X11 0X01 0x03
*IDrange(Program):0x01(1)~0xFF(255)
BroadcastCommandB.
STX CMD Length
Data
ETX
ID XY S X
Value 0x02 Variable 0x04 0x00 0x11 0x00 0x01 0x03
*AllLCDwilldothesameoperationsimultaneously.But,therewillbenoreturncommunication.(Onewaycommand)
Receive from MLCD -
STX CMD Length
Data
Check Sum ETX
ID Master
Value 0x02 Variable 0x02 Variable 0X01 Variable 0x03
*IDrange(Program):0x01(1)~0xFF(255)
*CheckSum:execute"Not"operationafteraddingallthevaluesin"STX~Data"area.
Command for removing the image data in seam area (On) or displaying all the data on the screen (Off) -
It is available only on Power On (Operative) status.
-
CMD: 0x74(On), 0x73(Off)
-
Send to MLCD
-
NormalCommandA.
STX CMD Length
Data
ETX
ID Master
Value 0x02 Variable 0x02 Variable 0X01 0x03
*IDrange(Program):0x01(1)~0xFF(255)
BroadcastCommandB.
STX CMD Length Data: ID ETX
Value 0x02 Variable 0x01 0x00 0x03
*MakeallLCD(Master/Slave)dothesameoperation.But,therewillbenoreturncommunication.(Onewaycommand)
Receive from MLCD -
STX CMD Length
Data
Check Sum ETX
ID Master
Value 0x02 Variable 0x02 Variable 0X01 Variable 0x03
*IDrange(Program):0x01(1)~0xFF(255)
*CheckSum:execute"Not"operationafteraddingallthevaluesin"STX~Data"area.
Configuration for automatic power on by AC power connection. -
It is available only on Power On (Operative) status.
-
CMD: 0x62(On), 0x63(Off)
-
Send to MLCD
-
NormalCommandA.
STX CMD Length
Data
ETX
ID Master
Value 0x02 Variable 0x02 Variable 0X01 0x03
*IDrange(Program):0x01(1)~0xFF(255)
BroadcastCommandB.
STX CMD Length Data: ID ETX
Value 0x02 Variable 0x01 0x00 0x03
*AllLCDwilldothesameoperationsimultaneously.But,therewillbenoreturncommunication.(Onewaycommand)
Receive from MLCD -
STX CMD Length
Data
Check Sum ETX
ID Master
Value 0x02 Variable 0x02 Variable 0X01 Variable 0x03
*IDrange(Program):0x01(1)~0xFF(255)
*CheckSum:execute"Not"operationafteraddingallthevaluesin"STX~Data"area..
Users can select Over-scan when input is DTV resolution from DVI. It is only available with DVI mode. -
CMD: 0xE4(On), 0xE5(Off)
-
It is usable only at Power on status.
-
Send to MLCD
-
NormalCommandA.
STX CMD Length
Data
ETX
ID Master
Value 0x02 Variable 0x02 Variable 0X01 0x03
*IDrange(Program):0x01(1)~0xFF(255)
BroadcastCommandB.
STX CMD Length Data: ID ETX
Value 0x02 Variable 0x01 0x00 0x03
*MakeallLCDdothesameoperation.But,therewillbenoreturncommunication.(Onewaycommand)
Receive from MLCD -
STX CMD Length
Data
Check Sum ETX
ID Master
Value 0x02 Variable 0x02 Variable 0X01 Variable 0x03
*IDrange(Program):0x01(1)~0xFF(255)
*CheckSum:Execute"Not"operationafteraddingallthevaluesin"STX~Data"area.