4.3. Connection of Control Cable - In case of using MSCS
• Control signal transmission can be connected by 2 different methods.
(RS-232C or Ethernet)
• RS-232C and Ethernet connection cannot be used simultaneously.
4.3.1. Connection of RS-232C Cable
• Maximum use of RS-232C with Daisy Chain connection is 30 sets or less, if you need
additional connection, use New MFC.(Max 30sets/1 port)
4.3.2. Connection of Ethernet Cable
• In case of Ethernet connection, the control PC should be connected to one of MPDP sets with
Ethernet cable. For the connection between the MPDP sets, they should be connected with
RS-232C cables.