- 52 - - 53 -
Go to "Control" in menu bar -> Tracking Control or press
"Ctrl+T" using keyboard to run "Tracking" window.
Press "Tracking Auto" button in order to run auto tracking.
In case alignment doesn't work through "Tracking Auto"
command, user can tune finely through "Manual".
Manual Tracking enables users to set Frequency, Phase,
LineStart and PixelStart.
Select panel ID which you want to adjust alignment.
Detail adjustment steps are as follows.
1) Tune "Phase" until the vertical lines are clearly adjusted..
2) Tune "LineStart" to adjust vertical alignment. "PixelStart" for horizontal alignment.
3) Adjust "Frequency" if alignment is still wrong.
If you adjust "Frequency", repeat step 1) and 2) to fit alignment.
Adjustable range is as follows
-The range of "Frequency" you can adjust is -50 to 50
-The range of "Phase" you can adjust is 0 to 63
-The range of "Linestart" you can adjust is -23 to 10
-The range of "Pixelstart" you can adjust is -50 to 40
Click "EXIT" button or press "Ctrl+X" using keyboard to close "Tracking" window.
When "Tracking" windows is on display, users cannot display "Picture Control"
window.
Even when "Tracking" window is on display, selecting panel ID is available by clicking
right button of mouse.
5.15. Tracking Control
Alignment adjustment is available when input source is PC.
Tracking Manual Window
5.14. Sync Control
It reduces the flashing effect for MPDP.
Select Menu -> Control -> Sync Control or press “Ctrl + N”to execute Sync Control.
MPDP ID for Sync Correction, Sync Correction Mode and Time will be displayed at the
Sync Correction Status window.
Select “Auto” for automatic Sync correction.
Select “Manual” for manual Sync correction.
Sync Correction time can be selected (Range: 0~255)
Sync Correction time will be reset as “0” when the Correction mode is changed from
“Manual” to “Auto.”
If Sync Correction Time is changed by user during “Auto” mode, it will be turned to
“Manual” mode automatically.
Sync Correction Status
OPM-4260 | OPM-4260R
Innitely Expandable

Table of Contents