5.4. Setting of LAN Port (In case of connecting to a LAN Hub)
This function is used to control the MPDP via LAN PORT.
* During the setting process, MPDP and control PC should be connected via RS-232C cable
only. Do not connect ethernet cable.
* After setting process, the control PC should be connected to one of MPDP sets with Ethernet
cable only. For the connection between the MPDP sets, they should be connected with
RS-232C cables.
n Network IP setting for MPDP
1) Execute the LAN Configurator V1.0 from installation CD.
2) Select Com Port and select "OPEN".
3) Select ID of MPDP which you want to control.
4) Turn off MPDP.
5) Type in IP Address.
6) Click "SET TCP/IP Info".
7) Click "GET TCP/IP Info." and Confirm the IP Address.
8) Close the LAN Configurator V1.0