- 40 - - 41 -
5.7. Multi-screen configuration
n Input the numbers of X and Y
− X is for the number of row and Y is for column.
− X and Y can be selected within the range from 1 to 15. The maximum MPDP quantity of MSCS
control is 100 sets.
− MPDP image of selected numbers of X and Y is displayed in the Screen configuration in one second
after setting the number.
Screen Configuration Setting
5.8. Selecting the command transmission method
• ONE PDP : Transmit Protocol Command to one MPDP.
• ALL PDP : Transmit the Protocol command sequentially to all connected MPDP sets.
• Broadcast : Transmit the Protocol command simultaneously to all connected MPDP sets.
※ INFO :
− Check the resolution of the input source. It is displayed at the upper right corner of the screen.
− Check the signal. If there is no input signal, "No signal" is displayed.
5.9. Power On/Off
1) Power On: Press On button in the Power Mode.
2) Power Off: Press Off button in the Power Mode.
3) Power off for Afterimage Mitigation: Power off after displaying a pattern to mitigate the afterimage.
Press Afterimage Mitigation button.
It needs about 10 second standby time before pressing the Power On button if the
power is newly connected. Without the standby time, it may cause malfunction.
In case of malfunction, disconnect the power plug and connect it again.
Caution
OPM-4260 | OPM-4260R
Innitely Expandable