Recording
Set On/Off of recording against Text input
Sync Text with
Select channel to synchronize with text.
Header check
There is a various types of data input from the external device (Access Control, POS, ATM etc). Like
the “Star Finger 007” protocol. If the device has implemented the protocol, it is just to connect the
device to the OSD.
If not, this is the parameter to analyse - how data is constructed from the text data that is input
continuously.
Namely, all data has the first and the end. Header indicates the information that already inserts to
inform its starting. Therefore, Header information is defined here to acknowledge its starting of a data.
The reason of 2 Header is to detect maximum 2 data out because each device can output various
data’s.
Delimiter
Delimiter value can be different according to the manufacturer, please, refer to the product manual or
seller.
Time out
Following lines defined here means maximum number of text line from one data. Even if there is
standardized data, there can be a short and long data. For example, there are 3 lines to write names
on ATM. But some may need only First name & Last name to register. Which it means requires only 1