3.1.6 Discharge over current
Cuts off discharging current if the current exceeds the trigger value, for [delay] seconds.
Reconnects after [release value] seconds.
3.1.7 Charge over temperature
Cuts off charging current if the probe temperature exceeds the trigger value.
Reconnects after the temp drops below the release value.
3.1.8 Charge under temperature
Cuts off charging current if the probe temp drops below the trigger value.
Reconnects after the probe temp rises above the release value.
3.1.9 Discharge over temperature
Cuts off discharging current if the probe temperature exceeds the trigger value.
Reconnects after the temp drops below the release value.
3.1.10 Discharge under temperature
Cuts off discharging current if the probe temp drops below the trigger value.
Reconnects after the probe temp rises above the release value.
3.2 Capacity Parameters
These parameters are used to display the battery capacity and to calculate the state of charge..