3.1.6 Discharge over current
Cuts off discharging current if the current exceeds the trigger value, for [delay] seconds.
Reconnects after [release value] seconds.
3.1.7 Charge over temperature
Cuts off charging current if the probe temperature exceeds the trigger value.
Reconnects after the temp drops below the release value.
3.1.8 Charge under temperature
Cuts off charging current if the probe temp drops below the trigger value.
Reconnects after the probe temp rises above the release value.
3.1.9 Discharge over temperature
Cuts off discharging current if the probe temperature exceeds the trigger value.
Reconnects after the temp drops below the release value.
3.1.10 Discharge under temperature
Cuts off discharging current if the probe temp drops below the trigger value.
Reconnects after the probe temp rises above the release value.
3.2 Capacity Parameters
These parameters are used to display the battery capacity and to calculate the state of charge..