B.2 Current Calibration
You will need an accurate current meter to perform current calibration, and it must be able to measure the
maximum current that the BMS is capable of withstanding. Most handheld meters will only measure up to 10
amps; these are not sufficient. We recommend a clamp meter capable of measuring DC current at greater
than 100 amps, at an accuracy better than +/- 2.0%. If purchasing a new clamp meter, always make 100%
sure that it will measure DC current. Cheaper models only measure AC current.
Note: At the time of writing, calibration can only be done via the iPhone app, or the JBDTools USB Windows
application. These instructions cover the iPhone app.
Open the app. Click on Config. Then Current Cal. A warning message will appear. Heed its advice and only
continue if you know what you’re doing.
B.2.1 Idle Current Calibration
Start by temporarily disconnecting all loads, and charge controllers. Double-check to make sure that nothing
is connected to the battery. The current displayed should be zero milliamps, or very close to it. Do not
proceed otherwise.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Overkill Solar BMS Series and is the answer not in the manual?

Overkill Solar BMS Series Specifications

General IconGeneral
BrandOverkill Solar
ModelBMS Series
CategoryControl Unit
LanguageEnglish

Related product manuals