4. Periodic Maintenance
4.1 Periodic Cable Check
Periodically perform a cable check:
1. Ensure that the cables have not loosened. Use a wrench or socket to tighten any connections or
terminals that have come loose.
2. Ensure that no wires have pinched or frayed; especially the balance wires.
4.2. Periodic Voltage Check
If the battery pack has gone unused for more than 6-12 months, it is recommended to check the cell voltages
with a multimeter. If they are low, charge the battery pack until the voltages are around 50-80%.
Use the iPhone / Android app and the bluetooth module to ensure that the cell voltages are not different by
more than XXXX millivolts when fully charged. If the cells are off by more than a few millivolts, first verify with
an external voltmeter. If the voltmeter doesn’t agree, then the BMS may need calibration (follow the steps in
Section 4). Otherwise, a top-balance might be necessary to bring them closer together. See Section 2.3 for
the top-balancing procedure.