EN20
Check item Trouble inspection location and remedial action
Reference
page
Is the main unit securely xed
with the suction cup?
Suction cup
z Did you forget attaching the suction cup to the
bottom surface of the main unit?
Attach the suction cup (supplied accessory) correctly.
EN18
z Is the suction cup tightly attached on the
installation surface?
Wipe o󰀨 dirt and moisture on the installation position su󰀩ciently.
(If the suction cup cannot be directly attached, remove
the suction cup mount of the mounting plate (supplied
accessory), and attach it on the installation surface.
Then, attach the suction cup on the mounting plate.)
EN18
Is water coming out of the
main spout?
Main spout
z Is the water supply hose bent or attened?
If it is, straighten it.
EN18–EN19
Is water coming out of the drain
hose when alkaline ion water passes
through the Alkaline Ionizer?
Drain hose
z Is the drain hose bent or attened?
If it is, straighten it.
EN19
z When water coming out from the drain
hose interrupts halfway, increase the height
di󰀨erence between the tip of the main spout
and the tip of the drain hose.
EN19
Installation 5
Check after installation
1
Run alkaline ion water for about 3 to 4 minutes to expel the air
inside the main unit.
Set the bypass selector to “ ”.
2 Press .
3 Turn on the water faucet to let the water ow.
z
When water is run immediately after installation, the water quality signal blinks approx. 20 seconds.
z If air is not removed, water is poorly drained o󰀨 from the main spout when stopped.
2
Check the items on P. EN20 to EN21. In the case of abnormality,
refer to the actions to be taken for each part.