Rated voltage, frequency, input current 220-240 V ~ , 50 Hz, 0.7 A
Rated power consumption Approx. 64 W (approx. 0.5 W during standby)
Main unit
Dimensions Approx. 168 (W) × 95 (D) × 333 (H) mm
Weight
Approx. 2.4 k
(approx. 2.8 k when full of water)
Temperature of water used by Alkaline Ionizer
Under 35 °C (under 80 °C for bypass selector)
Pressure of water used by Alkaline Ionizer (dynamic pressure)
70 kPa to 350 kPa
Usable water service pressure (static pressure)
70 kPa to 750 kPa
Electrolysis
Electrolysis method Continuous electrolysis
Output water volume
(ow of water produced)
2.0 L/min. [at 100 kPa water pressure]
Electrolysis capability selection
Alkaline: 3 levels; Acidic: 1 level
Continuous operation
capability
Approx. 10 minutes at room temperature (Note 1)
Electrolyzer life
Approx. 850 hours cumulative
(ion water production time, cleaning time only)
Electrolytic cleaning Auto cleaning method
Puried water output volume 2.4 L/min. [at 100 kPa water pressure]
Filtration ow volume 2.4 L/min. [at 100 kPa water pressure] (Note 2)
Cartridge Installed In the unit TK-AS500C-EX
Purication capacity
Free residual chlorine 12 000 L (Note 2,3)
Turbidity 12 000 L (Note 2,4)
Chloroform 12 000 L (Note 2,5)
Total trihalomethane 12 000 L (Note 2,5)
Bromodichloromethane 12 000 L (Note 2,5)
Dibromochloromethane 12 000 L (Note 2,5)
Bromoform 12 000 L (Note 2,5)
Tetrachloroethylene 12 000 L (Note 2,5)
Trichloroethylene 12 000 L (Note 2,5)
CAT (pesticide) 12 000 L (Note 2,3)
2-MIB (mold smell) 12 000 L (Note 2,3)
Soluble lead 12 000 L (Note 2,3)
1,2-DCE 12 000 L (Note 2,5)
Benzene 12 000 L (Note 2,5)
Geosmin (mold smell) 12 000 L (Note 2,3)
Phenols 12 000 L (Note 2,3)
PFOS and PFOA 12 000 L (Note 2,6)
Removable substances
Iron (particulate form) Can be removed (Note 7)
Aluminium (neutral) Can be removed (Note 7)
Guide for time to replace cartridge Approx. 2 years (Note 8)
Filter material
Non-woven fabric, activated carbon, ceramic, hollow ber membrane
Components which cannot be ltered out
Iron dissolved in water, heavy metals (silver, copper, etc.), salt (seawater)
Length of power cord Approx. 3 m
Power protection device Current fuse: 2.5 A
* All gures given are for a water temperature of 20 °C. * This product cannot convert hard water into soft water.
*
The total volume of water coming out of the main spout, drain hose is given as the run through water volume and daily volume of water used.
* Activated carbon uses powdered activated carbon and granular activated carbon.
(Note1) This period may be shorter depending on the water quality and usage environment.
(Note2)
The amount of water that can be used with Alkaline 1 to 3 and acidic water is equivalent to about 83 % of the ltration ow volume (water
purifying capacity)
.
(Note3) This value is for a removal rate of 80 % based on JIS S 3201 tests.
(Note4) This value is for a ltration ow volume of 50 % based on JIS S 3201 tests.
(Note5) This value is for a removal rate of 80 % based on JIS S 3201 Annex A tests.
(Note6) This value is for a removal rate of 80 % based on specication standard tests (JWPAS B standards) stipulated by the Japan
Water Purier Association (JWPA).
(Note7) This substance is for a removal rate of 80 % based on specication standard tests (JWPAS B standards) stipulated by the Japan
Water Purier Association (JWPA). Note that it is not stipulated as part of purication capacity.
(Note8)
This period applies when 15 liters of water are used a day. If 30 liters are used a day, the cartridge usage limit will be approximately one-half.
The period may also be signicantly less depending on the amount of water used and on its quality and pressure.
Specications
EN43
When necessary
English