GTWIN Operations
2-12
2.3.2 Parts Library Types
The parts library is organized as shown below.
Parts library
Library
Group
Color group
Explanation
Standard
All
None
This parts library conforms to conventional GTWIN.
Switch
These parts have a function for turning the corresponding
PLC bit device ON/OFF. A variety of functions can be
assigned to these parts.
Lamp
The display status of these parts changes depending on the
ON/OFF state of the corresponding PLC bit device.
Message
These parts have a function for switching their display
status according to the value of the corresponding PLC
device.
Data
Displays the numeric value of the PLC device on the GT
screen.
Bar Graph
These parts have a function for displaying the changes in
the value of the referenced PLC device as a bar graph.
Graphs can be vertical or horizontal.
Clock
These parts have a function for displaying the date and
time according to the referenced clock (the GT clock/PLC
clock). A single clock part displays one of the following
items: year, month, day, hour, minute, second, or day of
week.
Line Graph
These parts have a function for displaying the changes in
the value of the referenced PLC device as a line graph.
Alarm List
These parts are used to monitor PLC devices allocated to
error statuses and to display an alarm message on the GT
or record the history of error occurrence, etc. in the internal
memory when an error occurs.
Keyboard
These parts are used to enter numeric values that you want
to display with data parts.
Custom
When you want to create user-defined parts, these parts
can be used to edit the display of the parts to use. Three
types are available: switch, lamp, and message.
Switch
Real
Metallic
Pastel
Icon
Blue, Green,
Orange, Red,
White, Yellow
These switch parts have been designed into real, metallic,
pastel, and icon styles.
Lamp
Real
Metallic
Pastel
Same as above
These lamp parts have been designed into real, metallic,
and pastel styles.
Template
(Background)
Real
Metallic
Pastel
Blue, Green,
Orange, Red,
White, Yellow
These parts have been prepared for use as the background
colors of each screen.
Template
(PLC)
All
FP-XH
These parts are used to monitor the operation indicator
LEDs of the Panasonic PLC FP-XH-series.