97
KX-FLB802CX/KX-FLB812CX/KX-FLB802CXS/KX-FLB812CXS
11.1.3. SERVICE FUNCTION TABLE
Code Function Set Value Effective
Range
Default Remarks
501 Pause time set X 100 msec 001~600 030 ----------
503 Dial speed select 1:10 pps
2:20 pps
1, 2 1 ----------
507 V34 transmission start speed 0: Disable
1: 33.6
2: 31.2
3: 28.8
4: 26.4
5: 24.0
6: 21.6
7: 19.2
8: 16.8
0~8 1
508 V34 reception start speed 0: Disable
1: 33.6
2: 31.2
3: 28.8
4: 26.4
5: 24.0
6: 21.6
7: 19.2
8: 16.8
0~8 1
514 Bell signal detect time X 100msec 1~9 6 ----------
520 CED frequency select 1:2100 Hz
2:1100 Hz
1, 2 1 See Symptom/Countermeasure Table for long dis-
tance and international calls in (P.155).
521 International mode select 1:ON 2:OFF 1, 2 1 See Symptom/Countermeasure Table for long dis-
tance and international calls in (P.155).
522 Auto standby select 1:ON 2:OFF 1, 2 1 The resolution reverts to the default when transmis-
sion is complete.
523 Receive equalizer select 1: 0 km
2: 1.8 km
3: 3.6 km
4: 7.2 km
1~4 1 Set RX equalizer to automatic mode.
524 Transmission equalizer select 1: 0 km
2: 1.8 km
3: 3.6 km
4: 7.2 km
1~4 1
527 V.8 function select 1:OFF 2:ON 1, 2 2
529 Call Service Clear
550 Memory clear Refer to Memory Clear Specification (P.99).
551 ROM check
See (P.92).
552 DTMF single tone test 1:ON 2:OFF 1, 2 2
See (P.92).
553 Monitor on FAX communication
select
1:OFF
2:PHASE B
3:ALL
1~3 1 Sets whether to monitor the line signal with the
unit's speaker during FAX communication or not.
554 Modem test
See (P.92).
555 Scanner test
See (P.92).
556 Motor test & H.V.P.S. check 0
See (P.92).
557 LED test
See (P.92).
558 LCD test
See (P.92).
561 KEY test
See (P.92).
570 BREAK % select 1:61% 2:67% 1, 2 1 Sets the % break of pulse dialing according PBX.
571 ITS auto redial time set X number of
times
00~99 05 Selects the number of times that ITS is redialed
(not including the first dial).
573 Remote turn-on ring number set X number of
rings
00~99 10 Sets the number of rings before the unit starts to
operate TAM in the TEL mode.
590 FAX auto redial time set X number of
times
00~99 05 Selects the number of redial times during FAX com-
munication (not including the first dial).
591 FAX auto redial time disconnection
time set
X second 001~999 065 Sets the FAX redial interval during FAX communi-
cation.
592 CNG transmit select 1:OFF
2:ALL
3:AUTO
1~3 2 Lets you select the CNG output during FAX trans-
mission. ALL: CNG is output at phase A. AUTO:
CNG id output only when automatic dialing is per-
formed. OFF: CNG id not output at phase A. Refer
to (P.147).