Default Value 0
ENH_FOVR_ENABLE_n
For details about parameter names end with "_n", see 5.2.1 Configuration File Parameters
Value Format BOOLEAN
Description Specifies whether to enable Enhanced Failover mode.
Value Range
Y: Enable
N: Disable
Default Value
N
ENH_FOVR_RANDOM_TIMER_n
For details about parameter names end with "_n", see 5.2.1 Configuration File Parameters
Value Format BOOLEAN
Description Specifies whether the retry timer is a fixed value or a random value
when the unit re-sends a REGISTER request when a failover failure
has occurred.
Note
This setting is available only when "ENH_FOVR_ENABLE_n"
is set to "Y".
For the fixed value setting, see "REG_RTX_INTVL_n" in this
section.
Value Range
Y: Use a random value
N: Use a fixed value
Default Value
N
ENH_FOVR_RANDOM_MAX_TIME_n
For details about parameter names end with "_n", see 5.2.1 Configuration File Parameters
Value Format INTEGER
Description Specifies the maximum value, in seconds, of the retry timer, which
determines the interval for re-sending REGISTER requests, when the
retry timer is set to be a random value.
Note
This setting is available only when
"ENH_FOVR_RANDOM_TIMER_n" is set to "Y".
Value Range 10-86400
Default Value 15
ENH_FOVR_RANDOM_MIN_TIME_n
For details about parameter names end with "_n", see 5.2.1 Configuration File Parameters
Value Format INTEGER