Description Specifies whether the ringback tone is repeated.
Value Range 0–1
– 0: No Repeat
– 1: Repeat
Default Value 1
RINGBACK_TONE_TIMING
Value Format Comma-separated Integer
Description Specifies the pattern, in milliseconds, of ringback tones using up to
10 whole numbers (off 1, on 1, off 2, on 2…) separated by commas.
Note
• It is recommended that you set a value of 60 milliseconds or
more for the first value (off 1).
Value Range 0–16000 (msec) (0: Continuous)
Note
• Avoid setting 1–50 for any of the values.
Default Value 60,2000,3940
Web User Interface Reference Tone Timings
HOLD_ALARM_FRQ
Value Format Comma-separated Integer
Description Specifies the dual-tone frequencies, in hertz, of the hold alarm using
2 whole numbers separated by a comma.
Value Range 0, 200–2000 (Hz) (0: No tone)
Default Value 425
HOLD_ALARM_GAIN
Value Format INTEGER
Description Specifies the gain, in decibels, of the hold alarm.
Value Range -24–24 (dB)
Default Value 0
CW_TONE1_FRQ
Value Format Comma-separated Integer
Description Specifies the dual-tone frequencies, in hertz, of call waiting tone 1
using 2 whole numbers separated by a comma.
Value Range 0, 200–2000 (Hz) (0: No tone)
Default Value 425
5.3.33 Tone Settings
Document Version: 2017-07 Administrator Guide 325