CO  Line  Programming 
CPC  Signal  Detection  Outgoing  Set 
Description 
Enables  or  disables  CPC  Signal  Detection  during  the  time  between 
the  originated  CO  call  and  the  established  CO  call.  If  this  is 
enabled,  the  system  disconnects  the  line  with  the  time  set  in 
program  [405]  “CPC  Signal  Detection  Incoming  Set”  when  CPC 
Signal  is detected. 
Selection 
l 
CO  line  number: 
KX-TD816; 
01 through  08,  *  ( * 
=a11 CO  lines) 
KX-TD1232; 
01 through  24,  *  ( * 
=a11 CO  lines) 
l 
Enable 
(detection)  / 
Disable 
(no  detection) 
Default 
Disable 
Programming 
1. 
2. 
Enter  415. 
Display: 
CPC Outgoing  Asn 
Press 
NEXT. 
3. 
4. 
5. 
6. 
Display:  CO Line NO?-> 
Enter  a CO 
line number. 
To 
enter  CO line number  01, you can also press NEXT. 
Display  example:  C001:Disable 
Keep  pressing 
SELECT 
until  the  desired  selection  is 
displayed. 
Press 
STORE. 
To  program  another  CO  line,  press 
NEXT 
or 
PREV, 
or 
SELECT 
and  the  desired  CO 
line number. 
7. 
Repeat  steps  4 through  6. 
8. 
Press 
E,W. 
Conditions 
l 
Some  central  offices  (CO) may  send CPC-like  signals  during  the  dialing 
sequence  and  an attempt  to make  a call may  be terminated.  If your  CO 
is such  a type.  select  “Disable.” 
l 
Program  [405] “CPC Signal  Detection  Incoming  Set” is used  to set 
CPC  Signal  Detection  Time. 
l 
In the case  of  KX-TD1232,  COO1 through  CO12 are for the Master 
System  and  CO 13 through  CO24  are for the Slave,  if available. 
l 
To assign  all CO lines  to one  selection,  press  the  *  key  at step  3.  In 
this case,  the  display  shows  the contents  programmed  for COO 1. 
Feature  References 
Section  3, Features, 
Calling  Party  Control  (CPC)  Signal  Detection 
* Direct  Inward  System  Access  (DISA) 
4-94 