Details of Operation (Monitor Mode)
Alarm Display
A : FAlarm occurred
– : FNo alarms occurred
Over-regeneration alarm: over 85% of the acceptable
consumption of the regenerative discharge resistor
Overload alarm: over 85% of the acceptable load level
Battery alarm: under the acceptable voltage level
<Notes>
• The battery alarm is kept active until the control power is turned off.
Other alarms are kept displayed at least one second after the alarm event occurs.
Alarming criteria cannot be changed.
Acceptable load factor of the regenerative discharge resistor (unit : %)
For an external regenerative discharge resistor, Pr6C should be 0 or 1 to display the load factor.
Display of the load factor
Display the load factor as a percentage of the rated load (100%).
• See "Overload Protection: Time Limiting Characteristic" in Appendix.
Load factor (unit : %)
Display of the load factor
of the regenerative discharge resistor
Display the load factor of the regenerative discharge resistor as a percentage of the protective
operation level (100%).