- 16 -
How to Install
The motor can be installed either vertically or horizontally. Observe the following notes.
A Horizontal mounting
Place the motor with the cable outlet facing down to prevent the entry of oil and water.
B Vertical mounting
If the motor is coupled with a reduction gear, make sure that the oil in the reduction gear does not
enter into the motor.
Oil and Water Protections
A This motor(IP65 rating) can be used where it is subjected to water and/or oil drops, but is
not water or oilproof. Therefore, the motors should not be placed or used in such environ-
ment.
B If the motor is coupled with a reduction gear, use the motor should with oil seals to prevent
the reduction gear oil from entering into the motor.
C Don't use the motor with the cables being immersed in oil or water.
Installation
Motor
Location
A Indoors, where the driver is not subjected to rain water and direct sun beams.
B Avoid the place where the driver is subjected to corrosive gases, flammable gases, grind-
ing liquids, oil mists, iron powders and cutting particles.
C Place in a well-ventilated, and humid- and dust-free space.
D Easy maintenance, inspections and cleaning is also important.
Environmental Conditions
Item
Ambient temperature
Ambient humidity
Storage temperature
Storage humidity
Vibration
Conditions
0 to 40˚C (free from freezing)
Not greater than 90%RH (free from condensation)
-20 to 80˚C (free from condensation)
Not greater than 90%RH (free from condensation)
Not greater than 49m/s2 (5G) in operation; not greater than 24.5m/s2 (2.5G) at rest