- 21 -
The model numbers of non-fuse breakers and magnetic contactors shown in the above list are manufactured by
Matsushita Electric Works, Ltd.
The model numbers of noise filters shown in the above list are manufactured by Tokin Corporation.
<Notes>
When you use multiple drivers, determine the capacity of non-fuse breaker and noise filter according to the "total"
required power capacity (net value determined by the actual loads) of the drivers.
Terminal block and earth terminals
Wires should be copper conductors of a temperature rating of 60°C or above.
Screw tightening torque of larger than the allowable value (1.2 N-m for M4 and 2.0 N-m for M5) may damage the
terminal.
Earth wire diameter should be 2.0 mm2 (AWG14) or larger for 30W to 2.5kW, and 3.5 mm2 (AWG11) or larger for
3 to 5kW.
Main circuit wire
diameter
(L1, L2, L3,
U, V, W and E)
2.0mm
2
A. W. G. 14
3.5mm
2
A. W. G. 11
Terminals
on the
terminalblock
M5
Noise
filter
LF-340
LF-350
LF-360
ontrol
powerwire
diam-
eter (r and t)
0.75mm
2
A. W. G. 18
Magnetic contactor
(contacts)
BMF6352N
(3P+2a2b)
BMF6502N
(3P+2a2b)
BMF6652N
(3P+2a2b)
Non-fuse
breaker
(rated current)
BBP3-40
(40A)
BBP3-50
(50A)
Required Power
(at the rated load)
approx. 3.8kVA
approx. 4.5kVA
approx. 5.3kVA
approx. 6.0kVA
approx. 6.8kVA
approx. 7.5kVA
Output
2.5kW
3kW
3.5kW
4.0kW
4.5kW
5kW
Voltage
200V
Amplifier
Series
MSDA
MDDA
MFDA
MSDA
MDDA
MHDA
MGDA
MSDA
MDDA
MFDA
MSDA
MDDA
MHDA
MSDA
MDDA
MFDA
MGDA
MSDA
MDDA
MHDA
Preparations and Adjustments