- 41 -
43
1K
1K
SP
IM
42
GND
17
Measuring
instrument
or external
circuit
19
25
CZ
Maximum rating:
30V, 50mA
GND
High-speed
photo coupler
Analogue Monitor Output
This output is the velocity monitor signal
(SP) or torque monitor signal (IM).
The signal range is approx. 0 to ± 9V.
The output impedance is 1kΩ. Pay atten-
tion to the input impedance of your mea-
suring instruments and
external circuits connected.
<Resolution>
1) Velocity monitor signal (SP): 8r/min./
LSB calculated from 6V/3000r/min
(Pr07 = 3)
2) Torque monitor signal (IM): 0.4%/LSB
calculated from 3V/rated value (100%)
AO
Open Collector Output
• Outputs Z-phase signals among those
from the encoder. The outputs are non-
insulated.
Receive these signal with high-speed
photo coupler at controller side, since
these Z-phase signal width is normally
narrow.
PO2