- 49 -
• If you set a parameter that will become valid after a reset operation, " " will appear at writing complete. Turn
off the power and then turn it on again to make the change valid.
• You can re-write the parameter by keeping the UP button depressed at the parameter writing complete.
<Notes>
1.If a writing error occurs, return to the first step of the writing procedure, and repeat it.
2.Do not turn off the power during EEPROM writing. Otherwise a false data may be entered. If this happens, set all
parameters again, make sure that all the parameter values are correct, and then write them down to EEPROM.
Start writing (momentary message
will be displayed as shown in the
right figure).
Using the front touch panel
1) Turn the driver (power) ON.
2) Press SET button.
3) Keep pressing MODE button.
4) Select your desired
Parameter No. by using UP
and DOWN button.
5) Press SET button.
6) Change the value
using LEFT ARROW, UP and DOWN buttons.
7) Press SET button.
Select EPROM Writing Mode.
8) Keep pressing
MODE button
9) Press SET button.
10) Keep pressing UP button
(approx. 3 seconds). Bars in
the display increases as shown
in the right figure.
MODE
ID MODE
IM SP G
SET
SET
SET
SET
SET
Writing complete
MODE
Writing error
Preparetions and Adjustments