- 42 -
6.OPERATION
Alarm screen configuration
(1) Title bar: The window can be operated.
(2) Tool bar:
(Clear): Clear the current alarm.
After removing the cause, click this button, and the
current alarm will be cleared, and normal operation will
be restarted. However, it is impossible to clear alarm
that cannot be cleared by the alarm clearing input signal
from the amplifier. Turn off the power to the amplifier,
remove the cause, and re-apply the power.
(Clear): Clears the error history.
(Exit): Closes the parameter window.
(3) Current alarm display area
The number and name of the current alarm are
displayed.
(4) Error history display area
The order of occurrence of errors, alarm
numbers and error names are displayed.
■Notes:
・When Undervoltage, control power, Undervoltage, main power or
Overtravel inhibit input error occurs, a trip occurs. However, these
errors are not recorded in the error history.
・Up to 14 errors are stored. If the 15th error occurs, the oldest error is
deleted.
(1) Title bar
(2) Tool bar
(3) Current alarm display area
(4) Error history display area