Chapter 4Settings — [PROJECTOR SETUP] menu
ENGLISH - 153
Interrelation of luminance and runtime
The projector can be operated at arbitrary brightness and duration of use by combining the settings of [MAX
LIGHT OUTPUT LEVEL], [LIGHT OUTPUT], and [CONSTANT MODE] in [BRIGHTNESS CONTROL SETUP].
Interrelation of luminance and runtime is as follows. Make the settings depending on your desired duration of use
and brightness of the projected image.
Values of the luminance and runtime are rough estimations.
r To set the projector based on the duration of use
Duration of use
(hour)
When [CONSTANT MODE] is set to [OFF] When [CONSTANT MODE] is set to [AUTO] or [PC]
[MAX LIGHT
OUTPUT LEVEL]
(%)
[LIGHT
OUTPUT]
*1
(%)
Luminance (lm)
[MAX LIGHT
OUTPUT LEVEL]
(%)
[LIGHT OUTPUT]
(%)
Luminance (lm)
5 000 100.0 100.0 26 000 83.3 67.7 17 500
10 000 100.0 100.0 26 000 83.3 59.4 15 400
20 000 83.3 83.3 21 600 83.3 46.7 12 100
24 000 83.3 53.6 13 900 83.3 42.7 11 100
48 000 83.3 83.3 26.2 6 800
63 000 83.3 83.3 19.8 5 100
87 000 83.3 83.3 13.0 3 300
*1 The upper limit of the adjustment range is the value described in the [MAX LIGHT OUTPUT LEVEL] column in the table.
r To set the projector based on luminance
Luminance (lm)
When [CONSTANT MODE] is set to [OFF] When [CONSTANT MODE] is set to [AUTO] or [PC]
[MAX LIGHT
OUTPUT LEVEL]
(%)
[LIGHT
OUTPUT]
*1
(%)
Runtime (hour)
[MAX LIGHT
OUTPUT LEVEL]
(%)
[LIGHT OUTPUT]
(%)
Runtime (hour)
26 000 100.0 100.0 18 000
21 000 83.3 80.8 20 000
17 000 83.3 65.4 22 100 83.3 65.4 6 300
13 000 83.3 50.0 24 500 83.3 50.0 17 000
9 000 83.3 83.3 34.6 33 900
7 000 83.3 83.3 26.9 46 500
4 000 83.3 83.3 15.4 77 100
*1 The upper limit of the adjustment range is the value described in the [MAX LIGHT OUTPUT LEVEL] column in the table.
Note
f Under inuence of characteristics of each light source, conditions of use, installation environment, etc., the runtime may be shorter than the
estimation.
f The duration of use is referred to as the runtime when you use the projector successively. The duration of use is an estimated duration and
is not the warranty period.
f If the consolidated runtime of the projector exceeds 20 000 hours, replacement of the components inside the projector may be required. The
consolidated runtime can be conrmed in the [STATUS] screen. Refer to the [PROJECTOR SETUP] menu [STATUS] for details.
[LIGHT OUTPUT]
Adjust the brightness of light source.
The setting is reected when it is already set with “Initial setting (operation setting)” (x page 63) in the [INITIAL
SETTING] screen or with the [PROJECTOR SETUP] menu [OPERATION SETTING]. The [LIGHT OUTPUT]
setting is synchronized with the [PROJECTOR SETUP] menu [OPERATION SETTING] [LIGHT OUTPUT].
The most recent setting is reected in both items.
1) Press as to select [LIGHT OUTPUT].
2) Press qw to adjust.
Operation
Adjustment
Range of adjustment
Brightness Runtime
Press w.
The screen becomes brighter. The runtime becomes shorter.
8.0 % - 100.0 %
*1
Press q.
The screen becomes darker. The runtime becomes longer.
*1 The upper limit of the adjustment range is the value set in the [PROJECTOR SETUP] menu [OPERATION SETTING] [MAX LIGHT
OUTPUT LEVEL].