Chapter 6 Maintenance — Light source/temperature/lter indicators
ENGLISH - 213
r When the Smoke Cut Filter (Model No.: ET-SFR330) is attached
Indicator status Status Solution
Lighting in red
f The lter is clogged.
f The runtime of the lter exceeds the
recommended time to replace the
lter.
f The temperature around or outside
the projector is abnormally high.
f Replace the Smoke Cut Filter in the following cases. (x page 267)
g The lter is dirty.
g The recommended time to replace the lter has been exceeded.
f Remove any objects if they are blocking the air intake/exhaust port.
f Do not use the projector at an altitude of 1 400 m (4 593') or higher above
sea level.
Blinking in red f [FILTER TYPE]
*1
is set to [NORMAL]. f Set [FILTER TYPE]
*1
to [SMOKE CUT].
*1 [FILTER TYPE] can be set in the [PROJECTOR SETUP] menu → [FILTER SETTING] → [FILTER TYPE].
Note
f If the lter indicator <FILTER> is still lit or blinking after taking the measures, ask your dealer for repair.