Before Using this Device
SF4C Safety light curtain
52
Wiring for PNP output
K1
K2
S1
S2
S2
S2
K1 K2
+
%
-
+10
-15
24V
DC
(Brown) + V
(Pink) Test input / Reset input
(Yellow) Override input
(Red) Muting lamp output
(Green / Black) Auxiliary output
(Gray) Safety input 1
(Gray / Black) Safety input 2
(Shield) Output polarity setting wire
(Blue) 0V
(Orange) Synchronization +
(Orange / Black) Synchronization -
(Orange / Black) Synchronization -
(Orange) Synchronization +
(Brown) + V
(Gray) Large multi-purpose indicator input 1
(Sky-blue / White) Muting input 1
(Green) External device monitor input
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Shield) Output polarity setting wire
(Blue) 0V
(Gray / Black) Large multi-purpose indicator input 2
(Sky-blue / Black) Muting input 2
Gray cable
Gray cable
(with black line)
(Pale purple) Interlock setting input
Load
(Note 1 )
EmitterReceiver
Symbols in the wiring diagram
Switch S1
Test input/Reset input Vs to Vs - 3.5V (sink current: 5mA or less): OFF
Open: ON
Switch S2
Muting input/Override
input
Vs to Vs - 3.5V (sink current: 5mA or less): OFF
Open: ON
K1, K2 External device (forcibly guided relay or magnetic contactor)
Vs = Applied supply voltage