Magellan / Spectra SP 25
7.1.3 Entry Delay 1 (Full Arm) Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 03
Upon regular arming, the zone is Entry Delay 1 (see Entry Delay 1 Zones on page 24). Upon Stay/Sleep arming, the
zone is bypassed by the system. See Zone Definition Status on page 28 for any exceptions.
7.1.4 Entry Delay 2 (Full Arm) Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 04
Upon regular arming, the zone is Entry Delay 2 (see Entry Delay 2 Zones on page 24). Upon Stay/Sleep arming, the
zone is bypassed by the system. See Zone Definition Status on page 28 for any exceptions.
7.1.5 Follow Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 05
When a Regular, Stay, or Sleep armed Follow Zone opens, the control panel will immediately generate an alarm,
unless an entry delay zone opens first:
If a Regular/Stay/Sleep armed Follow Zone opens after an entry delay zone opens, the control panel waits until the
entry delay timer has elapsed before generating an alarm.
If a Regular/Stay/Sleep armed Follow Zone opens after more than one entry delay zone opens, the control panel
will wait until the entry delay timer of the zone that opened first has elapsed.
This feature is commonly used when a motion detector is protecting the area occupied by the entry point keypad. This
will prevent the motion detector from causing an alarm when a user enters through the entry point to disarm the
system. See Zone Definition Status on page 28 for any exceptions.
7.1.6 Follow (Sleep / Full Arm)
Sections [001] to [032]: Zones 1 to 32, First Digits = 06
Upon regular arming or sleep arming, the zone is Follow. Upon Stay arming, the zone is bypassed by the system. See
Zone Definition Status on page 28 for any exceptions.
7.1.7 Follow (Full Arm) Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 07
Upon regular arming, the zone is Follow (see Follow Zones on page 25). Upon Stay or Sleep arming, the zone is
bypassed by the system. See Zone Definition Status on page 28 for any exceptions.
7.1.8 Instant Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 08
When an armed Instant Zone opens, the control panel immediately generates an alarm. Instant Zones are commonly
used for windows, patio doors, skylights and other perimeter type zones. See Zone Definition Status on page 28 for
any exceptions.
7.1.9 Instant (Sleep / Full Arm) Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 09
When Regular or Sleep arming, the zone is Instant. When Stay arming, the zone is bypassed by the system. See Zone
Definition Status on page 28 for any exceptions.
7.1.10 Instant (Full Arm) Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 10
Upon Regular arming, the zone is Instant. Upon Stay or Sleep arming, the zone is bypassed by the system. See Zone
Definition Status on page 28 for any exceptions.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Magellan MG5050 EN and is the answer not in the manual?

Paradox Magellan MG5050 EN Specifications

General IconGeneral
Partitions2
Wireless Zones32
User Codes32
Event Buffer256
Remote ControlYes
Wireless KeypadsSupported
StayD ModeYes
RF Frequency433 MHz or 868 MHz
Users32
CompatibilityParadox wireless devices
CommunicationGSM, IP
TypeControl Panel
Power Supply16.5 VAC
Battery Backup12 VDC, 7 Ah
Operating Temperature0°C to 50°C
Humidity5% to 90% non-condensing
Zones32 (8 on-board)