42 Reference & Installation Manual
10.19 No Exit Delay Beeps and No Bell Squawk When Stay/Sleep Arming
Section [704]: Arming/Disarming Options
Option [7] OFF = No Exit Delay Beeps and No Bell Squawk When Stay/Sleep Arming Disabled
Option [7] ON = No Exit Delay Beeps and No Bell Squawk When Stay/Sleep Arming Enabled (default)
With this feature enabled, the control panel will prevent the bell or siren from squawking and the keypads from beeping during the
exit delay, whenever a partition is Stay/Sleep armed.
10.20 Exit Delay Termination
Section [700]: Arming/Disarming Options
Option [6] OFF = Exit Delay Termination (Disabled)
Option [6] ON = Exit Delay Termination Enabled (default)
When option [6] is enabled (ON), the panel will reduce the Exit Delay to 10 seconds when an Entry Delay zone is opened and
closed during the Exit Delay.
Example: 15 seconds into a 45 second Exit Delay, an Entry Delay zone opens and closes. The remaining 30 seconds is reduced
to 10 seconds.
10.21 Fast Exit
When the system is already Stay or Sleep armed: This feature will allow you to exit and keep the system armed. Press and hold
the [OFF] key for 3 seconds to start the exit delay. After the exit delay has elapsed, the system will switch to its previous arming
mode.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Magellan MG5050 EN and is the answer not in the manual?

Paradox Magellan MG5050 EN Specifications

General IconGeneral
Partitions2
Wireless Zones32
User Codes32
Event Buffer256
Remote ControlYes
Wireless KeypadsSupported
StayD ModeYes
RF Frequency433 MHz or 868 MHz
Users32
CompatibilityParadox wireless devices
CommunicationGSM, IP
TypeControl Panel
Power Supply16.5 VAC
Battery Backup12 VDC, 7 Ah
Operating Temperature0°C to 50°C
Humidity5% to 90% non-condensing
Zones32 (8 on-board)