14.11 Audible Trouble Warning Except AC Failure
Section [700]: General System Options
Option [3] OFF = Audible trouble warning except AC failure (default)
Option [3] ON = Audible trouble warning except AC failure
When this option is enabled the panel will generate an audible trouble warning on all troubles except AC failure.
14.12 Audible Trouble Warning on AC Failure
Section [700]: General System Options
Option [4] OFF = Audible trouble warning on AC failure (default)
Option [4] ON = Audible trouble warning on AC failure
When this option is enabled the panel will generate an audible trouble warning in the event of an AC failure.
14.13 Display Entry Delay on LCD keypad (K32LCD, K32LCD+)
Section [701]: General System Options
Option [7] OFF = Display entry delay on LCD keypad
Option [7] ON = Display entry delay on LCD keypad (default)
When this option is enabled the panel will display entry delays on the K32LCD and K32LCD+ keypad modules.
14.14 Display Exit Delay on LCD keypad (K32LCD, K32LCD+)
Section [701]: General System Options
Option [8] OFF = Display exit delay on LCD keypad
Option [8] ON = Display exit delay on LCD keypad (default)
When this option is enabled the panel will display exit delays on the K32LCD and K32LCD+ keypad modules.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Magellan MG5050 EN and is the answer not in the manual?

Paradox Magellan MG5050 EN Specifications

General IconGeneral
Partitions2
Wireless Zones32
User Codes32
Event Buffer256
Remote ControlYes
Wireless KeypadsSupported
StayD ModeYes
RF Frequency433 MHz or 868 MHz
Users32
CompatibilityParadox wireless devices
CommunicationGSM, IP
TypeControl Panel
Power Supply16.5 VAC
Battery Backup12 VDC, 7 Ah
Operating Temperature0°C to 50°C
Humidity5% to 90% non-condensing
Zones32 (8 on-board)