50 Reference & Installation Manual
12.21 Force Dial Option
Section [800]: Dialer Options
Option [5] OFF = Force Dial Disabled
Option [5] ON = Force Dial Enabled (default)
With option [5] is enabled, the panel will dial a telephone number even if no dial tone is present after 4 seconds.
12.22 Recent Closing Delay
Section [838]
000 = Disabled, 001 to 255 seconds, Default = Disabled
If after having armed the system, an alarm is generated within the period defined by the Recent Close Delay, the control panel will
attempt to transmit the Recent Close report code programmed in section [863].
12.23 Auto Test Report
Sections [840]
000 = Disabled, 001 to 255 days, Default = Disabled
Section [850]: Time (HH:MM)
The control panel will transmit the Test Report report code programmed into section [875] after the number of days programmed
into section [840] has elapsed at the time programmed into section [850]. Use the 24-hour clock to program the time (i.e. 6:30PM
= 18:30). The first Test Report will be transmitted within 24 hours after the feature is enabled at the time programmed in [850].
Example: Section [840] = 005 and section [850] = 13:00. The first Test Report will be sent at 1 PM that day and then the report
will be sent every 5 days at 1 PM.
12.23.1 Auto Test Report Transmission Options
Sections [800]
12.23.2 Armed Report Delay
Section [851]
000 = disabled, 001 to 255 minutes, Default = 5 min.
The Armed Report Delay determines the amount of time after an Arming event that the control panel will wait before
sending a report.
12.23.3 Disarmed Report Delay
Section [852]
000 = disabled, 001 to 255 minutes, Default = 60 min.
The Disarmed Report Delay determines the amount of time after an Disarming event that the control panel will wait
before sending a report.
12.24 Closing Delinquency Delay
Section [719]
000 = Disabled, 001 to 255 days, Default = Disabled
At midnight every day, the control panel will verify when the partition was last disarmed. If the partition has not been armed within
the time programmed in the Closing Delinquency Delay, the control panel will transmit a Closing Delinquency event to the
monitoring station.
Example: The Closing Delinquency Timer for partition 1 in section [719] is programmed for 005 days. The control panel verifies
when partition 1 was last disarmed at midnight every day. If partition 1 was not armed within the last 5 days, the panel will
transmit a Closing Delinquency event to the monitoring station. The Closing Delinquency Event and timer apply only to
partition 1.
[3] [4] Auto-Test Report Transmission Options
OFF OFF Transmit the test report code every time the days programmed in section [840] have elapsed at the time programmed in
section [850] (default).
OFF ON When disarmed: Transmit test report code every time the time programmed in section [852] has elapsed. When armed:
Transmit test report code every time the time programmed in section [851] has elapsed.
ON OFF The control panel will transmit the test report code every hour on the minute value programmed in section [850] (the last
two digits). Note that the first two digits of section [850] will be ignored. E.g. If 10:25 was programmed into section [850],
the test report code would be transmitted at the 25th minute of every hour, i.e. 11:25, 12:25, etc.
ON ON The test report code will be transmitted when any of the conditions of the second and third options listed above (options
[3] = OFF and [4] = ON / options [3] = ON and [4] = OFF) are met.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Magellan MG5050 EN and is the answer not in the manual?

Paradox Magellan MG5050 EN Specifications

General IconGeneral
Partitions2
Wireless Zones32
User Codes32
Event Buffer256
Remote ControlYes
Wireless KeypadsSupported
StayD ModeYes
RF Frequency433 MHz or 868 MHz
Users32
CompatibilityParadox wireless devices
CommunicationGSM, IP
TypeControl Panel
Power Supply16.5 VAC
Battery Backup12 VDC, 7 Ah
Operating Temperature0°C to 50°C
Humidity5% to 90% non-condensing
Zones32 (8 on-board)