30 Reference & Installation Manual
7.5 EOL Zones
Section [706]: Zone Options
Option [2] OFF = Zones do not use EOL resistors (default)
Option [2] ON = Zones require EOL resistors
If all detection devices connected to the control panel have input terminals that require 1K end of line resistors, enable option
[2] in section [706]. For details on using EOL resistors, see Single Zone Inputs on page 12.
7.6 ATZ Zone Doubling
Section [705]: General Zone Options
Option [1] OFF = ATZ zone doubling disabled (default)
Option [1] ON = ATZ zone doubling enabled
Enabling ATZ Zone Doubling allows you to install two detection devices per input terminal.
7.7 Tamper Input on ZX8 ID A (Panel + 1)
Section [706]: General Zone Options 2
Option [4] OFF = Zone A (default)
Option [4] ON = Tamper input
Enabling this option will make the first zone on the ZX8 ID A (Panel +1) a tamper input. By default, it is a zone.
7.8 Tamper Input on ZX8 ID B (Panel + 9)
Section [706]: General Zone Options 2
Option [5] OFF = Zone B (default)
Option [5] ON = Tamper input
Enabling this option will make the first zone on the ZX8 ID B (Panel +9) a tamper input. By default, it is a zone.
7.9 Tamper Input on ZX8 ID C (Panel + 17)
Section [706]: General Zone Options 2
Option [6] OFF = Zone C (default)
Option [6] ON = Tamper input
Enabling this option will make the first zone on the ZX8 ID C (Panel +17) a tamper input. By default, it is a zone.
7.10 ATZ Wiring Options
Section [705]: General Zone Options
Option [2] OFF = ATZ Series (default)
Option [2] ON = ATZ Parallel doubling enabled
ATZ Zone Doubling can be configured in either a series or parallel connection.
7.11 Zone Input 1 Becomes a 2-wire Smoke Input
Section [706]: General Zone Options
Option [3] OFF = Zone input 1 is a standard zone input (default)
Option [3] ON = Zone input 1 becomes a 2-wire smoke input
With this option enabled, zone input 1 becomes a 2-wire smoke input (all panels except SP5500).
7.12 Zone Timers
Sections [041] to [044]: Zones 1 to 4
001 to 255 X 10ms, Default = 060
The Zone Timer defines how quickly the control panel will respond to an open zone. The control panel will not display an open
zone on the keypad or generate an alarm until the programmed Zone Timer has elapsed. All other zone definitions and options
do not come into effect until the Zone Timer has elapsed. This feature prevents any momentary glitches from causing an alarm or
unnecessary reporting.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Magellan MG5050 EN and is the answer not in the manual?

Paradox Magellan MG5050 EN Specifications

General IconGeneral
Partitions2
Wireless Zones32
User Codes32
Event Buffer256
Remote ControlYes
Wireless KeypadsSupported
StayD ModeYes
RF Frequency433 MHz or 868 MHz
Users32
CompatibilityParadox wireless devices
CommunicationGSM, IP
TypeControl Panel
Power Supply16.5 VAC
Battery Backup12 VDC, 7 Ah
Operating Temperature0°C to 50°C
Humidity5% to 90% non-condensing
Zones32 (8 on-board)