20 Programming Guide
Partition Timers
Refer to the Installer Quick Menu on page 65 for alternate entry/exit and bell cut-off timer programming.
System Programming
[742] Partition 2 Options
Option
OFF ON
[1]
Auto-arm on time
Disabled Enabled
[2]
Auto-arm on no movement
Disabled Enabled
[3]&[4]
Auto-arm arming mode
See Table See Table
[5] Switch to stay arming if no entry delay zone is opened
Disabled Enabled
[6] Follow zones become entry delay 2 when delay zone is bypassed
Disabled Enabled
Section Data Description
[745] ____/____/____ (000 to 255) seconds Partition 1 exit delay (default 060)
[746] ____/____/____ (000 to 255) seconds Partition 2 exit delay (default 060)
[747] ____/____/____ (000 to 255) minutes Partition 1 bell cut-off (default 004)
[748] ____/____/____ (000 to 255) minutes Partition 2 bell cut-off (default 004)
[749] ____/____/____ (000 to 255) x 15 minutes Partition 1 no movement (default 000)
[750] ____/____/____ (000 to 255) x 15 minutes Partition 2 no movement (default 000)
[761] ____/____:____/___ HH: MM Auto-arm on time Partition 1 (default 00:00)
[762] ____/____:____/____ HH: MM Auto-arm on time Partition 2 (default 00:00)
[700] General System Options
Option OFF ON
[2] Battery charging (350mA or 700mA)*
350mA
700mA
[3] Audible trouble warning (except AC failure)
Disabled Enabled
[4] Audible trouble warning on AC failure
Disabled Enabled
[6] Exit delay termination
Disabled Enabled
[7] Tamper supervision on the bus module
Disabled Enabled
* Does not apply to SP4000 systems
[702] Panic Options
Option OFF ON
[1] Panic 1
Disabled Enabled
[2] Panic 2
Disabled Enabled
[3] Panic 3
Disabled Enabled
[4] Panic 1: Report only or audible alarm
Report only Audible
[5] Panic 2: Report only or audible alarm
Report only Audible
[6] Panic 3: Report only or audible alarm
Report only Audible
[703] Arming/Disarming Options
Option OFF ON
[5] Restrict arming on battery failure
Disabled Enabled
[6] Restrict arming on tamper failure (Zone + Bus Module
+ Wireless PGM)
Disabled Enabled
[7] Restrict arming on wireless supervision trouble (Wireless zones +
Wireless PGM)*
Disabled Enabled
* Does not apply to SP4000 systems.
[704] Arming/Disarming Options
Option OFF ON
[1] Regular arming switches to force arming
Disabled
Enabled
[2] Stay arming switches to stay force arming
Disabled
Enabled
[3] Sleep arming switches to sleep force arming
Disabled
Enabled
[3] [4]
OFF OFF Regular
OFF ON Sleep
ON OFF Stay