Magellan / Spectra SP 41
Installer Function Keys
Use the following instructions to access the Installer Function features.
RF jamming 3 344 - RF receiver jam detection XH - RF Jamming Restoral
GSM/GPRS module Rf interference restore 3 552 - Radio transmitter restore YK - Communication restore
GSM/GPRS network restore 3 552 - Radio transmitter restore YK - Communication restore
GSM/GPRS supervision restore 3 552 - Radio transmitter restore YK - Communication restore
GSM/GPRS fail to communicate restore 3 354 - Communication restore YK - Fail to communicate restore
IP network restore 3 552 - Radio transmitter restore YK - Communication restore
IP supervision restore 3 552 - Radio transmitter restore YK - Communication restore
IP fail to communicate restore 3 354 - Communication restore YK - Fail to communicate restore
Combus fault 1 333 - Expansion module failure ET - Expansion trouble
Module tamper 1 341 - Expansion module tamper TA - Tamper alarm
Module AC fail 1 342 - AC failure on module AT - Module AC fail
Module battery fail 1 338 - Battery failure on module YT - Module battery fail
Bus fault restore 3 333 - Expansion module failure restore ER - Expansion restoral
Module tamper restore 3 341 - Expansion module tamper restore TR - Tamper restoral
Module AC fail restore 3 342 - AC restored on module AR - Module AC fail restore
Module battery fail restore 3 338 - Battery failure on module YR - Module battery fail restore
Cold start 1 3A8 - System shutdown RR - Power up
Test report engaged 1 6A2 - Periodic test report TX - Test report
PC software communication finished 1 412 - Successful - download access RS - Remote program success
Installer on site 1 627 - Program mode entry LB - Local program
Installer programming finished 1 628 - Program mode exit LS - Local program success
Maintenance in 1 627 - Program mode entry LB - Local program
Maintenance out 1 628 - Program mode exit LS - Local program success
Closing delinquency 1 654 - System inactivity CD - System inactivity
Manual trigger test in 1 6A1 - Manual trigger test in TS - Manual trigger test in
Manual trigger test out 3 6A1 - Manual trigger test out TS - Manual trigger test out
Exit error 1 374 - Exit error EE - Exit error
RF module low battery 1 384 - RF transmitter low battery XT - Transmitter battery trouble
RF module battery restore 3 384 - RF transmitter battery restore XR - Transmitter battery restoral
RF zone supervision lost 1 381 - Loss of supervision - RF US - Untype zone supervision
RF zone supervision restore 3 381 - Supervision restore - RF UR - Untyped zone restoral
RF module supervision lost 1 381 - Loss of supervision- RF US - Untype zone supervision
RF module supervision restore 3 381 - Loss of supervision- RF restore UR - Untyped zone restoral
RF module tamper 1 145 - Expansion module tamper ES - Expansion device tamper
RF module tamper restore 3 145 - Expansion module tamper restore EJ - Expansion device restore
Paramedic alarm 1 1AA - Medical MA - Medical alarm
Zone forced 1 57A - Zone forced XW - Zone forced
Zone included 3 57A - Zone included UU - Zone included
Function Action Description
Test Report
[
ENTER]+[INSTALLER CODE] + [MEM]
Send the “Test Report” report code programmed in section [875]
(page 38) to the monitoring station
Cancel Communication
[
ENTER]+[INSTALLER CODE] + [STAY]
Cancels all communication with the WinLoad / BabyWare software or
with the monitoring station until the next reportable event
Answer WinLoad /
BabyWare Software
[
ENTER]+[INSTALLER CODE] + [SLEEP]
Will force the console to answer an incoming call from the monitoring
station that is using the WinLoad / BabyWare software
Call WinLoad / BabyWare
Software
[
ENTER]+[INSTALLER CODE] + [BYP]
Will dial the PC telephone number programmed in section [915]
(page 22) in order to initiate communication with a computer using
the WinLoad / BabyWare software
Installer Test Mode
[ENTER]+[INSTALLER CODE] + [TBL]
The installer test mode will allow you to perform walk tests where the
siren will squawk to indicate opened zones. Press the [TBL] key
again to exit
System Event Default Contact ID Report Code Default SIA Report Code

Other manuals for Paradox Spectra SP4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Spectra SP4000 and is the answer not in the manual?

Paradox Spectra SP4000 Specifications

General IconGeneral
Partitions2
User Codes32
Event Buffer256 events
StayD ModeYes
Expandable via Expansion ModulesYes
BusYes, 4-wire expansion bus
Battery Backup12V 7Ah
PGM Outputs2