40 Programming Guide
Automatic Report Code List
System Event Default Contact ID Report Code Default SIA Report Code
Arming with User Code (##) 3 4A1 - Close by user CL - Closing report
Auto arming 3 4A3 - Automatic close CA - Automatic closing
Late to close 3 452 - Late to close OT - Late to close
No movement 3 452 - Late to close NA - No activity
Partial arming 1 456 - Group bypass CG - Close area
Quick arming 3 4A8 - Quick arm CL - Closing report
Arm with PC software 3 4A7 - Remote arm/disarm CQ - Remote arming
Keyswitch arming 3 4A9 - Keyswitch arming CS - Keyswitch arming
Disarm with User Code (##) 1 4A1 - Open by user OP - Opening report
Disarm after alarm* with User Code (##) 1 4A1 - Open by user OP - Opening report
Cancel alarm** with User Code (##) 1 4A6 - Cancel by user OR - Disarm from alarm
Auto-arming cancellation 1 464 - Deferred open/close CE - Closing extend
Disarm with PC software 1 4A7 - Remote arm/disarm OQ - Remote disarming
Disarm after an alarm with PC software 1 4A7 - Remote arm/disarm OR - Disarm from alarm
Cancel alarm with PC software 1 4A6 - Cancel by user OR - Disarm from alarm
Cancel paramedic alarm 1 4A6 - Cancel by user MH - Medical alarm restore
Keyswitch disarm 1 4A9 - Keyswitch disarm OS - Keyswitch disarm
Keyswitch disarm after alarm 1 4A1 - Keyswitch disarm after alarm OS - Keyswitch disarm after alarm
Keyswitch cancel alarm 1 4A6 - Keyswitch cancel alarm OS - Keyswitch cancel alarm
Zone bypassed (##) 1 57A - Zone bypass UB - Untyped zone bypass
Zone alarm (##) 1 13A - Burglary alarm BA - Burglary alarm
Fire alarm (##) 1 11A - Fire alarm FA - Fire alarm
Zone alarm restore (##) 3 13A - Burglary alarm restore BH - Burglary alarm restore
Fire alarm restore (##) 3 11A - Fire alarm restore FH - Fire alarm restore
24Hr Gas Alarm (##) 1 151 - Gas detected GA - Gas Alarm
24Hr Heat Alarm (##) 1 153 - Loss of heat KA - Heat Alarm
24Hr Water Alarm (##) 1 154 - Water leakage WA - Water Alarm
24Hr Freeze Alarm (##) 1 152 - Refrigeration ZA - Freeze Alarm
24Hr Gas Alarm Restore (##) 3 151 - Gas restore GR - Gas Alarm Restore
24Hr Heat Alarm Restore (##) 3 153 - Heat restore KR - Heat Alarm Restore
24Hr Water Alarm Restore (##) 3 154 - Water restore WR - Water Alarm Restore
24Hr Freeze Alarm Restore (##) 3 152 - Freeze restore ZR - Freeze Alarm Restore
24Hr Hold-up Alarm 1 12A - Panic Alarm PA - Panic Alarm
24Hr Hold-up Alarm Restore 3 12A - Panic Alarm Restore PR - Panic Restore
Panic 1 - emergency 1 12A - Panic alarm PA - Panic alarm
Panic 2 - medical 1 1AA - Medical alarm MA - Medical alarm
Panic 3 - fire 1 115 - Pull station FA - Fire alarm
Recent closing 3 459 - Open/Close CR - Recent closing
Global zone shutdown 1 575 - Group bypass CG - Close area
Duress alarm 1 121 - Duress HA - Hold-up alarm
Keypad lockout 1 421 - Access denied JA - User code tamper
Zone shutdown (##) 1 57A - Zone bypass UB - Untyped zone bypass
Zone tampered (##) 1 144 - Sensor tamper TA - Tamper alarm
Zone tamper restore (##) 3 144 - Sensor tamper restore TR - Tamper restoral
TLM Trouble 1 351 - Telco 1 fault LT - Phone Line Trouble
AC failure 1 3A1 - AC loss AT - AC trouble
Battery failure 1 3A9 - Battery test failure YT - System battery trouble
Auxiliary supply trouble 1 3AA - System trouble YP - Power supply trouble
Bell output current limit 1 321 - Bell 1 YA - Bell fault
Bell absent 1 321 - Bell 1 YA - Bell fault
Clock lost 1 626 - Time/date inaccurate JT - Time changed
Fire loop trouble 1 373 - Fire trouble FT - Fire trouble
Communication fail 1 354 - Communication fail YC -Fail to communicate
RF jamming 1 344 - RF receiver jam detection XQ - RF Jamming
GSM/GPRS module RF interference 1 552 - Radio transmitter disabled YS - Communication trouble
GSM/GPRS network failure 1 552 - Radio transmitter disabled YS - Communication trouble
GSM/GPRS supervision lost 1 552 - Radio transmitter disabled YS - Communication trouble
GSM/GPRS fail to communicate 1 354 - Communication fails YC - Fail to communicate
IP network failure 1 552 - Radio transmitter disabled YS - Communication trouble
IP supervision lost 1 552 - Radio transmitter disabled YS - Communication trouble
IP fail to communicate 1 354 - Communication fails YC - Fail to communicate
TLM trouble restore 3 351 - Telco 1 fault restore LR - Phone line restoral
AC failure restore 3 3A1 - AC loss restore AR - AC restoral
Battery failure restore 3 3A9 - Battery test restore YR - System battery restoral
Auxiliary supply trouble restore 3 3AA - System trouble restore YQ - Power supply restored
Bell output current limit restore 3 321 - Bell 1 restore YH - Bell restored
Bell absent restore 3 321 - Bell 1 restore YH - Bell restored
Clock programmed 3 625 - Time/date reset JT - Time changed
Fire loop trouble restore 3 373 - Fire trouble restore FJ - Fire trouble restore
Fail to communicate with monitoring station 3 354 - Fail to communicate YK - Communication fails
* An armed system is or was in alarm and was disarmed by a user.
** A disarmed system is or was in alarm (e.g. 24Hr. zone) and was disarmed by a user.

Other manuals for Paradox Spectra SP4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Spectra SP4000 and is the answer not in the manual?

Paradox Spectra SP4000 Specifications

General IconGeneral
Partitions2
User Codes32
Event Buffer256 events
StayD ModeYes
Expandable via Expansion ModulesYes
BusYes, 4-wire expansion bus
Battery Backup12V 7Ah
PGM Outputs2