Magellan / Spectra SP 7
System Codes
Panel Reset
Performing a panel reset will reset all programmable sections to factory default values.
SP4000 panels:
1. Verify installer lock is disabled.
2. Remove the battery and AC power from the control panel.
3. Remove all connected wires and devices from the PG1 and zone 1 terminals.
4. Short the PG1 and zone 1 terminals with a wire.
5. Reconnect the AC and battery power to the control panel.
6. Wait for 10 seconds and remove the wire.
All other MG/SP panels:
To reset other MG/SP panels, press and hold the panel’s RESET button until the STATUS LED flashes (5 seconds). Release the RESET
button and push it again within 2 seconds. Performing a manual panel reset will not clear bus module troubles.
To reset the panel to default using section programming, see section [950] in Important Settings and Modes on page 6.
Viewing Version Numbers
Installer Code (Default: 0000 / 000000)
The Installer code is used to enter programming mode, which allows you to program
everything except user codes. To change the default code, go to section [397] on
page 50 and refer to section [701] option [1] on page 50.
Maintenance Code (No Default)
The Maintenance code is used to enter programming mode, which allows you to
program everything except for user codes and communication settings (sections
[395], [397], [398], [815], [816], [817], [910], [911], [970], and [975]). To set the default
code, go to section [398] on page 50 and refer to section [701] option [1] on page 50.
System Master Code (Default: 1234 / 123456)
The System Master code can use any arming method and can program user codes.
To change the default code, go to section [399] on page 50 and refer to section [701]
option [1] on page 50.
Example:
Version
01.42
Digits 1-4
Step Action Details When Viewing Keypad Version
1. Enter Viewing Mode:
- For panel version, enter section [980].
- For keypad version, enter Installer Programming,
then press and hold [ARM].
The first digit is displayed
(usually “0”)
Digit 1 [
ARM] is illuminated
2. Press [
ENTER] The second digit is displayed Digit 2 [SLEEP] is illuminated
3. Press [ENTER] The third digit is displayed Digit 3 [STAY] is illuminated
4. Press [
ENTER] The fourth digit is displayed Digit 4 [OFF] is illuminated
NOTE: K10V/H / K636 keypad version numbers cannot be viewed.