EasyManuals Logo

Paradox Spectra SP4000 Programming Guide

Paradox Spectra SP4000
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #30 background imageLoading...
Page #30 background image
30 Programming Guide
* Section [220] PGM 1 Activation Event default = (Option B Remote Assignment) Button pressed on Any remote/Any partition.
Section [222] PGM 2 Activation Event default = (Option C Remote Assignment) Button pressed on Any remote/Any partition.
NOTE: See Button Options Table on page 52.
Event Description
[236] PGM 9: Activation Event (____/____) (____/____) (____/____) 00/00/00
[237] Deactivation Event (____/____) (____/____) (____/____) 00/00/00
[238] PGM 10: Activation Event (____/____) (____/____) (____/____) 00/00/00
[239] Deactivation Event (____/____) (____/____) (____/____) 00/00/00
[240] PGM 11: Activation Event (____/____) (____/____) (____/____) 00/00/00
[241] Deactivation Event (____/____) (____/____) (____/____) 00/00/00
[242] PGM 12: Activation Event (____/____) (____/____) (____/____) 00/00/00
[243] Deactivation Event (____/____) (____/____) (____/____) 00/00/00
[244] PGM 13: Activation Event (____/____) (____/____) (____/____) 00/00/00
[245] Deactivation Event (____/____) (____/____) (____/____) 00/00/00
[246] PGM 14: Activation Event (____/____) (____/____) (____/____) 00/00/00
[247] Deactivation Event (____/____) (____/____) (____/____) 00/00/00
[248] PGM 15: Activation Event (____/____) (____/____) (____/____) 00/00/00
[249] Deactivation Event (____/____) (____/____) (____/____) 00/00/00
[250] PGM 16: Activation Event (____/____) (____/____) (____/____) 00/00/00
[251] Deactivation Event (____/____) (____/____) (____/____) 00/00/00
Event Group # Sub-group #
00 = Zone OK 01 to 32 = Zone number
99 = Any zone number
01 = Zone open
02 = Partition status
00 to 01= N/A
02 = Silent alarm
03 = Buzzer alarm
04 = Steady alarm
05 = Pulsed alarm
06 = Strobe
07 = Alarm stopped
08 = Squawk ON (Partition 1 only)
09 = Squawk OFF (Partition 1 only)
10 = Ground start (Partition 1 only)
11 = Disarm partition
12 = Arm partition
13 = Entry delay started
14 = Exit delay started
15 = Pre-alarm delay
16 = Report confirmation
99 = Any partition status event
03 = Bell status (Partition 1 only)
00 = Bell OFF
01 = Bell ON
02 = Bell squawk arm
03 = Bell squawk disarm
99 = Any bell status event
Section Event Group # Sub-Group #
Partition # (99 for
both partitions)
Default

Other manuals for Paradox Spectra SP4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Spectra SP4000 and is the answer not in the manual?

Paradox Spectra SP4000 Specifications

General IconGeneral
Partitions2
User Codes32
Event Buffer256 events
StayD ModeYes
Expandable via Expansion ModulesYes
BusYes, 4-wire expansion bus
Battery Backup12V 7Ah
PGM Outputs2