EasyManua.ls Logo

Parker 514C-04 - Setting-Up & Commissioning; Option Switches

Parker 514C-04
43 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-1 Setting up & Commissioning
514C Product Manual
Chapter 4 Setting-Up & Commissioning
OPTION SWITCHES
Speed Feedback
SW1/1
SW1/2
FEEDBACK VOLTAGE
OFF
ON
10 - 25V
USE P10 TO TRIM
ON
ON
25 - 75V
MAXIMUM SPEED
OFF
OFF
75 - 125V
TO REQUIRED
ON
OFF
125 - 325V
VALUE
TABLE 4.1 Full speed tachogenerator/armature feedback voltage.
Example:
(a) Customer wishes to run motor at 1500rpm with a 60V/1000rpm tachogenerator.
Feedback voltage = 90V.
From Table 4.1 set SW1 OFF SW2 OFF adjust P10 to give desired speed.
(b) Customer wishes to run motor at 2000rpm with 320V armature.
Feedback voltage = 320V
From Table 4.1 set SW1 ON SW2 OFF adjust P10 to give desired speed.
Note:- It is necessary to set these switches for both tachogenerator and armature voltage feedback.
General Purpose Switches
SW1/3
Speed Feedback
(OFF)
Tachogenerator Feedback for Speed Control.
(ON)
Armature Voltage Feedback for Speed Control.
SW1/4
Zero Output
(OFF)
Zero Speed Output.
(ON)
Zero Setpoint Output.
SW1/5
Current Meter
(OFF)
Bipolar Output.
(ON)
Modulus Output.
SW1/6
Ramp Isolate
(OFF)
Ramp Connected.
(ON)
Ramp Isolated.
SW1/7
Standstill Logic
(OFF)
Disabled.
(ON)
Enabled.
SW1/8
Current Demand
(OFF)
T18 = Current Demand Input.
(ON)
T18 = Current Demand Output.
SW1/9
Contactor Drop Out
on Over-Current
(OFF)
Contactor Drops Out on Over Current trip
(ON)
Contactor does not Drop Out on Over Current trip
SW1/10
Setpoint Comparator.
(OFF)
Total Setpoint.
(ON)
Ramped Setpoint Input.
Default switch settings are
SW1/1 = Off SW1/2 = On SW1/3 = On SW1/4 = Off SW1/5 = Off SW1/6 = Off
SW1/7 = Off SW1/8 = On SW1/9 = Off SW1/10 = Off