4-1 Setting up & Commissioning
514C Product Manual
Chapter 4 Setting-Up & Commissioning
OPTION SWITCHES
Speed Feedback
TABLE 4.1 Full speed tachogenerator/armature feedback voltage.
Example:
(a) Customer wishes to run motor at 1500rpm with a 60V/1000rpm tachogenerator.
Feedback voltage = 90V.
From Table 4.1 set SW1 OFF SW2 OFF adjust P10 to give desired speed.
(b) Customer wishes to run motor at 2000rpm with 320V armature.
Feedback voltage = 320V
From Table 4.1 set SW1 ON SW2 OFF adjust P10 to give desired speed.
Note:- It is necessary to set these switches for both tachogenerator and armature voltage feedback.
General Purpose Switches
Tachogenerator Feedback for Speed Control.
Armature Voltage Feedback for Speed Control.
T18 = Current Demand Input.
T18 = Current Demand Output.
Contactor Drop Out
on Over-Current
Contactor Drops Out on Over Current trip
Contactor does not Drop Out on Over Current trip
Default switch settings are
SW1/1 = Off SW1/2 = On SW1/3 = On SW1/4 = Off SW1/5 = Off SW1/6 = Off
SW1/7 = Off SW1/8 = On SW1/9 = Off SW1/10 = Off
This manual was downloaded on www.sdsdrives.com
+44 (0)117 938 1800 - info@sdsdrives.com